GT-G3066P3000VV-X.X-C Enclosed-Metal ICT/ITE Power Supply

GT-G3066P3000VV-X.X-C
GT-G3066P3000VV-X.X-C, ICT/ITE Power Supply, Enclosed-Metal, Single Output Power supply Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), 3 Positon Terminal Block, Output Rating: 3000 Watts, Power rating with convection cooling (W) , 12-48V in 0.1V increments, Approvals: WEEE; Ukraine; GOST-R; CE; VCCI; Class I; cULus; RoHS; China RoHS;GT-G3066P3000VV-X.X-C, ICT/ITE Power Supply, Enclosed-Metal, Single Output Power supply Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), 3 Positon Terminal Block, Output Rating: 3000 Watts, Power rating with convection cooling (W) , 12-48V in 0.1V increments, Approvals: WEEE; Ukraine; GOST-R; CE; VCCI; Class I; cULus; RoHS; China RoHS;
Information
Model NumberGT-G3066P3000VV-X.X-C
Agency Documentshttp://www.globtek.info/certs/GT-G3066PWWWWVV-X.X-C/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0Oa000000MEVSUEA5
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for MedicalContact GlobTek for more information
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0Oa000000MEVSUEA5
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MEVSUEA5
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MEVSUEA5
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeEnclosed-Metal
TechnologySingle Output Power supply Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz)
Max Input Current (A)36A / 115VAC, 18A / 230VAC
Max Output Power Rating (W)3000
Output Voltage Range (V)12-48
EfficiencyN/A
Ingress ProtectionIPX0
Size (mm)127x127x305
EnclosureUser-added image
User-added image
User-added image
User-added image
User-added image
User-added image
User-added image
User-added image
User-added image
 
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
GT-G3066P300012*122503000
GT-G3066P300015*152003000
GT-G3066P300024*241253000
GT-G3066P300027*271112997
GT-G3066P300048*4862.53000
* (Final ordering #/Part No to be defined)
Specifications
Features:
Universal AC input / Full range
Programmable output Voltage (30% ~ 105%)
Programmable output Current (40% ~ 105%)
+5V / 0.5A auxiliary output
High power density 10.8w / in3
Forced current sharing at parallel operation
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure

ELECTRICAL SPECIFICATIONS:
Output
DC Voltage Range: 12V 15V 24V 27V 48V
Rated Current 250A: 200A 125A 111A 62.5A
Current Range: 0 ~ 250A 0 ~ 200A 0 ~ 125A 0 ~ 111A 0 ~ 62.5A
Rated Power: 3000W 3000W 3000W 3000W 3000W
Ripple & Noise (Max.): Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
Voltage Adj. Range: ±5.0% Typical adjustment by potentiometer (VR1)
Voltage Tolerance: Note.3 ±1.0%
Line Regulation: ±0.5%
Load Regulation: ±0.5%
Setup, Rise Time: 800ms, 200ms at full load
Hold Up Time (Typ.): 16ms / 230VAC at full load

Input
Voltage Range: Note.4 90 ~ 264VAC, 127 ~ 370VDC
Frequency Range: 47 ~ 63Hz
Power Factor (Typ.):0.98 / 230VAC, 0.99 / 115VAC at full load
Efficiency (Typ.): 87% 88% 89% 89% 90%
AC Current (Typ.): 36A / 115VAC, 18A / 230VAC
Inrush Current (Typ.): 60A / 115VAC, 90A / 230VAC
Leakage Current: < 2.5mA / 240VAC

Protection
Over Load: 105 ~ 110% rated output power.Protection type: Constant current limit, Latch-style (Recovery after reset AC power ON or inhibit)
Over Voltage: Variable OVP, 120 ±5% Vout. Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Over Temperature: 80 ±5°C.Protection type: Shut down o/p voltage (Auto recovery after temperature goes down)

Function
Auxiliary Power: 5V / 0.5A (±3%)
Remote ON / OFF Control: External switch or NPN Transistor to turn ON / OFF
Power OK Signal: Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Output Voltage Trim: Adjustment of output voltage is between 30 ~ 100% of rated output
Output Current Trim: Adjustment of output current is between 40 ~ 105% of rated output
Parallel (Current Sharing): Please refer to function

Environment
Working Temp.: -25 ~ +60°C (Refer to output load de-rating curve)
Working Humidity: 20 ~ 90% RH non-condensing
Storage Temp. & Humidity: -40 ~ +85°C, 10 ~ 95% RH
Temp. Coefficient: ±0.02% / °C (0 ~ 50°C)
Vibration: 10 ~ 500Hz, 1G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6-2007

Safety & EMC
Safety Standards: Certified UL 60950-1; EN 60950-1
Withstand Voltage: I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC), 1min
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
EMI Conduction & Radiation: Certified EN 55022; EN 61000-6-3
Harmonic Current: Certified EN 61000-3-2; EN 61000-3-3
EMS Immunity: Certified EN 61204-3; EN 55024; EN 61000-6-1, IEC 61000-4-2, 3, 4, 5, 6, 8, 11

Others
MTBF: 73.570K HRS Certified MIL-HDBK-217F
Cooling: Load and temperature control fan
Dimension (WxHxH)v 127x127x305 mm / 5.000x5.000x12.008 inch
Packing: 6.6kg; 4pcs / 27.4kg / 2.1CUFT

Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection, only one unit will operate if the total output load is less than 5% of the rated load condition.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Conduct this test without enclosure.
Derating CurveUser-added image

 
Qty (ea.)/Carton4
Individual Box/Gift Box Size (mm)350*130*130
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)TBD
Gross Weight (kg)27.4
Label Width (mm)110.0
Label Height (mm)30.0
Input Configuration
Description3 Positon Terminal BlockShanghai Elinker P/N: LG103-5.0
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
User-added imageUL60950-1, cULus to UL 60950-1 E170507
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf

User-added image  
CE Certification
nullClass I Earth Ground
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
Request Info